RADIO IMMUNOASSAY TUMOR MARKERS

NSE

Immunoradiometric assay for quantitative determination of neuron specific enolase (NSE) in human serum

Summary

  • KFDA Registration No

    14-3156

  • CAT No

    RC09

  • TEST METHOD

    IRMA

  • SAMPLE VOLUME

    50 ul

  • INCUBATION TIME

    60'RT

  • STD RANGE

    0-120 ng/ml

Download File

Intended Use

Immunoradiometric assay for quantitative determination of neuron specific enolase (NSE) in human serum

PRINCIPLE OF THE ASSAY

The present method is based upon two anti-NSE monoclonal antibodies recognizing two different epitopes of the molecule. One antibody is adsorbed to the solid phase (coated tube), the other - labeled with lodine-125 is used as tracer. The sample to be tested is first incubated in the coated tube. Following this incubation and after an aspirating / washing cycle, the labeled antibody is added to each coated tube, where it is bound to the solid phase by means of the antigen in the standards and (if present) in samples. The amount of binding will be directly proportional to the antigen concentration. After tracer incubation, another washing / aspirating cycle will remove any liquid reagent residue.
The radioactivity in the tubes is measured in a gamma counter.

Use Precaution

Be careful when handling all samples, reagents, or devices used in the test as they may be the source of infection.
All reagents, human body samples, etc. are handled at the designated location.

  1. Do not use mixed reagents from different lots.
  2. Do not use reagents beyond the expiration date.
  3. Use distilled water stored in clean container.
  4. Use an individual disposable tip for each sample and reagent, to prevent the possible cross-contamination among the samples.
  5. Store the unused coated tubes at 2~8ºC in the appropriate bags with silica gel and accurately sealed.
  6. If large quantity of assay would be performed at one time, there might be substantial time variation between 60 tubes at one time to minimize time variation. Also, do not exceed 10 minutes for entire pipetting.
  7. Wear disposable globes while handling the kit reagents and wash hands thoroughly afterwards.
  8. Do not pipette by mouth.
  9. Do not smoke, eat or drink in areas where specimens or kit reagents are handle.
  10. Handle samples, reagents and loboratory equipments used for assy with extreme care, as they may potentially contain infectious agents.
  11. When samples or reagents happen to be split, wash carefully with a 3% sodium hypochlorite solution.
  12. Dispose of this cleaning liquid and also such used washing cloth or tissue paper with care, as they may also contain infectious agents.
  13. Avoid microbial contamination when the reagent vial be eventually opend or the contents be handled.
  14. Use only for IN VITRO.